|
Application Notes
|
Optimal working dilution should be determined by the investigator.
|
|
Protocol
|
This ELISA Pair Set is a solid phase sandwich ELISA (Enzyme-Linked Immunosorbent Assay). It utilizes a monoclonal antibody specific for Cystatin SN / CST1 coated on a 96-well plate. Standards and samples are added to the wells, and any Cystatin SN / CST1 present binds to the immobilized antibody. The wells are washed and a horseradish peroxidase conjugated rabbit anti-Cystatin SN / CST1 monoclonal antibody is then added, producing an antibody-antigen-antibody "sandwich". The wells are again washed and TMB substrate solution is loaded, which produces color in proportion to the amount of Cystatin SN / CST1 present in the sample. To end the enzyme reaction, the stop solution is added and absorbances of the microwell are read at 450 nm.
|
|
Reagent Preparation
|
- Dilute the capture antibody to the working concentration in CBS. Immediately coat a 96-well microplate with 100 μL per well of the diluted capture antibody. Seal the plate and incubate overnight at 4 °C.
2. Aspirate each well and wash with at least 300 μL wash buffer, repeating the process two times for a total of three washes. Complete removal of liquid at each step is essential for good performance. After the last wash, remove any remaining wash buffer by inverting the plate and blotting it against clean paper towels. 3. Block plates by adding 300 μL of blocking buffer to each well. Incubate at room temperature for a minimum of 1 hour. 4. Repeat the aspiration/wash as in step 2. The plates are now ready for sample addition.
|
|
Assay Procedure
|
- Add 100 μL of sample or standards in sample dilution buffer per well. Seal the plate and incubate 2 hours at roomtemperature.
2. Repeat the aspiration/wash as in step 2 of plate preparation. 3. Add 100 μL of the detection antibody, diluted in antibody dilution buffer, to each well. Seal the plate and incubate 1hour at room temperature. 4. Repeat the aspiration/wash as in step 2 of plate preparation. 5. Add 200 μL of substrate solution to each well. Incubate for 20 minutes at room temperature (if substrate solutionis not as requested, the incubation time should be optimized). Avoid placing the plate in direct light. 6. Add 50 μL of stop solution to each well. Gently tap the plate to ensure thorough mixing. 7. Determine the optical density of each well immediately, using a microplate reader set to 450 nm.
|
|
Calculation of Results
|
Calculate the mean absorbance for each set of duplicate standards, controls and samples. Subtract the mean zero standard absorbance from each. Construct a standard curve by plotting the mean absorbance for each standard on the y-axis against the concentration on the x-axis and draw a best fit curve through the points on the graph. To determine the concentration of the unknowns, find the unknowns' mean absorbance value on the y-axis and draw a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the x-axis and read the concentration. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor. Alternatively, computer-based curve-fitting statistical software may also be employed to calculate the concentration of the sample.
|
|
Restrictions
|
For Research Use only
|